Description: HI70300-023 is a GroLine storage solution prepared with reagent grade chemicals that can be used to ensure optimum performance of your pH and ORP electrodes. It is necessary to store a pH electrode in a solution in order to keep the glass membrane of the pH electrode hydrated. Ideally a storage solution should be used; never store an electrode in distilled or deionized water. The Hanna Instruments storage solution is specifically formulated to minimize microbial growth and to prevent any diffusion/osmotic effects from storing a probe in a solution with the highly concentrated inner reference electrolyte. Storing your pH and/or ORP electrodes in a storage solution will also keep the junction clear. Maintaining the hydrated layer and clear junction will help to ensure a fast and reliable measurement. In the case of cleaning your pH electrode in one of our cleaning solutions, we recommend soaking the electrode in the HI70300-023 GroLine storage solution for at least one hour before taking measurements. Special formulation to minimize microbial growth and osmotic/diffusion effects between the solution and inner reference electrolyte Manufactured specifically for pH and ORP electrodes HI70300-023 is a GroLine storage solution that can be used to store your pH electrode*. To ensure an optimum response time, the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. The HI70300-023 should also be used to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements. * Never store pH or ORP electrodes in distilled or deionized water. Doing so will shorten the life of the sensor. Air tight bottle with tamper-proof seal Ensures quality and freshness of solution Each bottle marked with lot number and expiration date. Hanna storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle. HI7061-023 is the GroLine general purpose cleaning solution that can be used for a variety of applications. Electrodes can become dirty from use and will produce inaccurate results even as they read correctly in a pH buffer. Hanna's cleaning solutions eliminate impurities and residues that are left on electrode surfaces when immersed in samples during measurement or when stored incorrectly. Hanna suggests cleaning the bulb and junction of your electrode on a regular basis to ensure that the probe is always clean and to prevent any clogging of the junction. Specially formulated for cleaning electrodes Air tight seal to ensure quality Expiration date and lot number The most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note, because during calibration, the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI7061-023 cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings. Air tight bottle with tamper-proof seal Ensures quality and freshness of solution Each bottle marked with lot number and expiration date. Hanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.
Price: 42.95 USD
Location: Elgin, South Carolina
End Time: 2024-12-27T22:20:49.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Brand: Hanna Instruments